Specifications
Secondary Winding:
2
Isolation Voltage(Vrms):
4kV
Primary Winding(s):
2
Secondary Side Voltage:
115V;230V
Output Current:
2.8A;1.4A
Primary Side Voltage:
115V;230V
Mfr. Part #:
ECO-330-230
Package:
Screw Terminals
Key Attributes
Model Number: ECO-330-230
Product Description

Product Overview

The Signal ECO Series EcoTran Standard Series Transformers are chassis-mount transformers designed for reliable power conversion. Featuring split bobbin construction for superior isolation and no exposed metallic surfaces, these transformers offer enhanced safety. The touch-safe terminal design eliminates potential shock hazards, making them suitable for a wide range of industrial applications. They are compliant with various international safety standards and offer dual secondary outputs for flexible series or parallel connection.

Product Attributes

  • Brand: Signal
  • Series: ECO Series EcoTran Standard Series
  • Construction: Split Bobbin
  • Terminal Type: Touch Safe Terminals (IP20 type) with screw/binding clamp for hard wiring and optional Fast-On
  • Exterior Surfaces Rating: UL 94 V2
  • Insulation System: UL 1446 Class F (155C)
  • Agency Certifications: IEC 61558-1, parts 2-4, 2-6; UL 1446 Class F; UL Listed to UL 5085-1, UL5085-2, CSA C22.2 No. 66.1-06, CSA C22.2 No. 66.2-06; compliant, EU/EC Declaration of Conformity / TUV Rheinland
  • Customization: Custom versions available upon request.

Technical Specifications

Part Number Power Rating (VA) Primary Voltage Secondary Series Output Secondary Parallel Output Dielectric Strength Leakage Current Dimensions (L x W x H inches) Mounting Screw Size Weight (lbs)
ECO-105-24 105 115/230 V 50/60 Hz 24 VCT @ 4.3 A 12 V @ 8.7 A 4000 V <30 A 3.54 x 4.17 x 3.78 #10 3.7 (1.68)
ECO-140-24 140 115/230 V 50/60 Hz 24 VCT @ 5.8 A 12 V @ 11.6 A 3.54 x 4.17 x 4.17 #10 4.6 (2.08)
ECO-170-24 170 115/230 V 50/60 Hz 24 VCT @ 7.0 A 12 V @ 14.0 A 3.54 x 4.17 x 4.57 #10 5.4 (2.45)
ECO-200-24 200 115/230 V 50/60 Hz 24 VCT @ 8.3 A 12 V @ 16.6 A 3.54 x 4.17 x 4.57 #10 5.6 (2.54)
ECO-330-24 330 115/230 V 50/60 Hz 24 VCT @ 13.7 A 12 V @ 27.5 A 4.96 x 5.35 x 4.50 #10* 9.1 (4.13)
ECO-450-24 450 115/230 V 50/60 Hz 24 VCT @ 18.7 A 12 V @ 37.5 A 4.96 x 5.35 x 4.90 #10* 11.5 (5.21)
ECO-105-28 105 115/230 V 50/60 Hz 28 VCT @ 3.7 A 14 V @ 7.4 A 4000 V <30 A 3.54 x 4.17 x 3.78 #10 3.7 (1.68)
ECO-140-28 140 115/230 V 50/60 Hz 28 VCT @ 5.0 A 14 V @ 10.0 A 3.54 x 4.17 x 4.17 #10 4.6 (2.08)
ECO-170-28 170 115/230 V 50/60 Hz 28 VCT @ 6.0 A 14 V @ 12.0 A 3.54 x 4.17 x 4.57 #10 5.4 (2.45)
ECO-200-28 200 115/230 V 50/60 Hz 28 VCT @ 7.1 A 14 V @ 14.2 A 3.54 x 4.17 x 4.57 #10 5.6 (2.54)
ECO-330-28 330 115/230 V 50/60 Hz 28 VCT @ 11.7 A 14 V @ 23.4 A 4.96 x 5.35 x 4.50 #10* 9.1 (4.13)
ECO-450-28 450 115/230 V 50/60 Hz 28 VCT @ 16.0 A 14 V @ 32.0 A 4.96 x 5.35 x 4.90 #10* 11.5 (5.21)
ECO-105-40 105 115/230 V 50/60 Hz 40 VCT @ 2.6 A 20 V @ 5.2 A 4000 V <30 A 3.54 x 4.17 x 3.78 #10 3.7 (1.68)
ECO-140-40 140 115/230 V 50/60 Hz 40 VCT @ 3.5 A 20 V @ 7.0 A 3.54 x 4.17 x 4.17 #10 4.6 (2.08)
ECO-170-40 170 115/230 V 50/60 Hz 40 VCT @ 4.2 A 20 V @ 8.4 A 3.54 x 4.17 x 4.57 #10 5.4 (2.45)
ECO-200-40 200 115/230 V 50/60 Hz 40 VCT @ 5.0 A 20 V @ 10.0 A 3.54 x 4.17 x 4.57 #10 5.6 (2.54)
ECO-330-40 330 115/230 V 50/60 Hz 40 VCT @ 8.2 A 20 V @ 16.4 A 4.96 x 5.35 x 4.50 #10* 9.1 (4.13)
ECO-450-40 450 115/230 V 50/60 Hz 40 VCT @ 11.3 A 20 V @ 22.6 A 4.96 x 5.35 x 4.90 #10* 11.5 (5.21)
ECO-105-48 105 115/230 V 50/60 Hz 48 VCT @ 2.2 A 24 V @ 4.4 A 4000 V <30 A 3.54 x 4.17 x 3.78 #10 3.7 (1.68)
ECO-140-48 140 115/230 V 50/60 Hz 48 VCT @ 2.9 A 24 V @ 5.8 A 3.54 x 4.17 x 4.17 #10 4.6 (2.08)
ECO-170-48 170 115/230 V 50/60 Hz 48 VCT @ 3.5 A 24 V @ 7.0 A 3.54 x 4.17 x 4.57 #10 5.4 (2.45)
ECO-200-48 200 115/230 V 50/60 Hz 48 VCT @ 4.1 A 24 V @ 8.2 A 3.54 x 4.17 x 4.57 #10 5.6 (2.54)
ECO-330-48 330 115/230 V 50/60 Hz 48 VCT @ 6.8 A 24 V @ 13.7 A 4.96 x 5.35 x 4.50 #10* 9.1 (4.13)
ECO-450-48 450 115/230 V 50/60 Hz 48 VCT @ 9.4 A 24 V @ 18.8 A 4.96 x 5.35 x 4.90 #10* 11.5 (5.21)
ECO-105-230 105 115/230 V 50/60 Hz 230 VCT @ 0.45 A 115 V @ 0.91 A 4000 V <30 A 3.54 x 4.17 x 3.78 #10 3.7 (1.68)
ECO-140-230 140 115/230 V 50/60 Hz 230 VCT @ 0.61 A 115 V @ 1.2 A 3.54 x 4.17 x 4.17 #10 4.6 (2.08)
ECO-170-230 170 115/230 V 50/60 Hz 230 VCT @ 0.74 A 115 V @ 1.5 A 3.54 x 4.17 x 4.57 #10 5.4 (2.45)
ECO-200-230 200 115/230 V 50/60 Hz 230 VCT @ 0.87 A 115 V @ 1.7 A 3.54 x 4.17 x 4.57 #10 5.6 (2.54)
ECO-330-230 330 115/230 V 50/60 Hz 230 VCT @ 1.40 A 115 V @ 2.8 A 4.96 x 5.35 x 4.50 #10* 9.1 (4.13)
ECO-450-230 450 115/230 V 50/60 Hz 230 VCT @ 2.00 A 115 V @ 4.0 A 4.96 x 5.35 x 4.90 #10* 11.5 (5.21)

* Mounting screw size for 330 VA and 450 VA models.

Optional: DIN Rail's Clip & Spring

Optional dimensions for Fast-On terminals: .195 x .310 (4X) or 0.23 x 0.375 (4X)