Product Overview
The Belfuse A41 Triple Output Series transformers are designed for regulated power supplies requiring international safety certification. These chassis-mount transformers offer triple output capabilities, providing a 5 VDC output alongside either 12 VDC or 15 VDC. They integrate the performance features of the split bobbin A41 series and are suitable for applications demanding international safety compliance. Custom versions are available upon request.
Product Attributes
- Brand: Belfuse (Signal Transformer)
- Series: A41 Triple Output Series
- Mounting Style: Chassis Mount
- Insulation Class: Class F (155 C)
- Flammability Rating: Bobbin and shroud material meet UL 94-V0
- RoHS Compliant: Yes
- Agency Certifications:
- UL 1446 (File # E66312)
- UL recognized to UL 506 / UL 5085-2 (File # E63829)
- CSA certified to C22.2 No. 66.1 (File # 221070)
- VDE certified to VDE 0805 / EN 60950 (File # 1448)
Technical Specifications
| Model | VA | DC Output | Size | Weight (lbs/kg) | Mechanical Dimensions (Inches) | Mounting Dimensions (Inches) |
|---|---|---|---|---|---|---|
| A41-25-512 | 25 | 5 V @ 1.25 A, 12 V @ 150 mA | 25 VA | 1.25 (0.57) | L: 2.81, W: 2.14, H: 2.31 | A: 2.00, B: 1.12, C: 0.31, ML: 0.18, MW: 2.37 |
| A41-25-515 | 25 | 5 V @ 1.25 A, 15 V @ 130 mA | 25 VA | 1.25 (0.57) | L: 2.81, W: 2.14, H: 2.31 | A: 2.00, B: 1.12, C: 0.31, ML: 0.18, MW: 2.37 |
| A41-43-512 | 43 | 5 V @ 2 A, 12 V @ 300 mA | 43 VA | 1.6 (0.73) | L: 3.12, W: 2.14, H: 2.68 | A: 2.25, B: 1.12, C: 0.31, ML: 0.18, MW: 2.81 |
| A41-43-515 | 43 | 5 V @ 2 A, 15 V @ 250 mA | 43 VA | 1.6 (0.73) | L: 3.12, W: 2.14, H: 2.68 | A: 2.25, B: 1.12, C: 0.31, ML: 0.18, MW: 2.81 |
| A41-80-512 | 80 | 5 V @ 3.5 A, 12 V @ 600 mA | 80 VA | 2.8 (1.27) | L: 2.50, W: 2.53, H: 3.06 | A: , B: 1.37, C: 0.31, ML: 0.18, MW: 2.00 |
| A41-80-515 | 80 | 5 V @ 3.5 A, 15 V @ 500 mA | 80 VA | 2.8 (1.27) | L: 2.50, W: 2.53, H: 3.06 | A: , B: 1.37, C: 0.31, ML: 0.18, MW: 2.00 |
| General Specification | Details |
|---|---|
| Power | 25 VA to 80 VA |
| Dielectric Strength | 4000 Vrms Hipot |
| Primaries | Dual primaries (115/230 V - 50/60 Hz) |
| Secondaries | Dual complementary outputs (5 VDC with 12 VDC or 5 VDC with 15 VDC) |
| Terminals | Solder lug / quick connect type terminals |
| Leakage Current | Meets UL 60601-1, IEC/EN 60601-1 |
| Mounting Style | Chassis Mount |
| Mounting Screw | #6 |
2411272205_Bel-Fuse-A41-25-512_C17488553.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible