Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Signal CL2 Series Transformer with UL 1585 Recognition Bel Fuse CL2-20-24 RoHS Compliant PCB Mount Design factory
<
quality Signal CL2 Series Transformer with UL 1585 Recognition Bel Fuse CL2-20-24 RoHS Compliant PCB Mount Design factory
>
Specifications
Secondary Winding:
1
Isolation Voltage(Vrms):
4kV
Primary Winding(s):
2
Secondary Side Voltage:
24V
Output Current:
833mA
Primary Side Voltage:
115V;230V
Mfr. Part #:
CL2-20-24
Package:
Through Hole-6P,57.2x47.6mm
Key Attributes
Model Number: CL2-20-24
Product Description

Product Overview

Signal's CL2 Series Class 2 Transformers are designed for printed circuit board mounting, offering both inherently and non-inherently limited options. These transformers are UL 1585 / UL 5085 recognized and feature a split bobbin construction for effective insulation without the need for an electrostatic shield. They are suitable for a wide range of power requirements from 2.5 VA to 50 VA, with dual primaries (115/230 V, 50/60 Hz) and single secondaries. The insulation system is Class F (155 C) and the bobbin and shroud material is rated UL 94V0 for flammability. These transformers are RoHS Compliant.

Product Attributes

  • Brand: Signal
  • Series: CL2 Series
  • Mounting Type: Printed Circuit Mount
  • Limitation Type: Inherently or Non-Inherently Limited
  • Agency Certifications: UL recognized to UL 1585 / UL 5085-3 Class 2, File # E116583; CSA certified to C22.2 #66.1
  • Insulation System: Class F (155 C)
  • Flammability Rating: Bobbin and shroud material rated UL 94V0
  • RoHS Compliant: Yes
  • Customization: Custom versions available upon request.

Technical Specifications

Product Name Secondary RMS Rating Secondary Fuse Required VA Dimensions (Inches) L x W x H* Pin Dimension A x B (Inches) Mounting Dimension C (Inches) Mounting Screw Size Qty Weight (lbs)
CL2-20-12 12 V @ 1.66 A N/A* 20.0 2.25 x 1.87 x 1.62 0.40 x 0.40 1.46 #4 2 0.90 (0.41)
CL2-20-24 24 V @ 0.833 A N/A* 20.0 2.25 x 1.87 x 1.62 0.40 x 0.40 1.46 #4 2 0.90 (0.41)
CL2-30-12 12 V @ 2.50 A 3.0 A** 30.0 2.62 x 2.18 x 1.56 0.55 x 0.27 1.68 #6 4 1.15 (0.52)
CL2-30-24 24 V @ 1.25 A 1.75 A** 30.0 2.62 x 2.18 x 1.56 0.55 x 0.27 1.68 #6 4 1.15 (0.52)
CL2-50-12 12 V @ 4.20 A 5.0 A** 50.0 3.00 x 2.50 x 1.83 0.60 x 0.30 1.90 #6 4 1.70 (0.77)
CL2-50-24 24 V @ 2.10 A 2.5 A** 50.0 3.00 x 2.50 x 1.83 0.60 x 0.30 1.90 #6 4 1.70 (0.77)
CL2-2.5R-12 12 V @ 0.20 A N/A* 2.5 1.62 x 1.43 x 1.12 0.20 x 0.25 1.06 #4 2 0.25 (0.11)
CL2-2.5R-24 24 V @ 0.10 A N/A* 2.5 1.62 x 1.43 x 1.12 0.20 x 0.25 1.06 #4 2 0.25 (0.11)
CL2-5.0R-12 12 V @ 0.42 A N/A* 5.0 1.62 x 1.43 x 1.37 0.20 x 0.40 1.06 #4 2 0.37 (0.17)
CL2-5.0R-24 24 V @ 0.20 A N/A* 5.0 1.62 x 1.43 x 1.37 0.20 x 0.40 1.06 #4 2 0.37 (0.17)
CL2-10R-12 12 V @ 0.83 A N/A* 10.0 1.87 x 1.56 x 1.37 0.20 x 0.40 1.25 #4 2 0.53 (0.24)
CL2-10R-24 24 V @ 0.42 A N/A* 10.0 1.87 x 1.56 x 1.37 0.20 x 0.40 1.25 #4 2 0.53 (0.24)

* Dimension H represents the total distance from the seating plane to the uppermost surface, stand offs and/or risers inclusive.
* Inherently limited
** Non-inherently limited (secondary fuse requirements below)
Maximum secondary fuse value specified.

General Specifications

  • Power: 2.5 VA to 50 VA
  • Dielectric Strength: 4000 Vrms Hipot
  • Primaries: Dual primaries, 115/230 V, 50/60 Hz
  • Secondaries: Single secondary
  • Class 2 Rating: Inherently or non-inherently limited
  • Electrostatic Shield: Not necessary, split bobbin construction

Contact Information

  • Address: 128 Atlantic Avenue, Lynbrook, NY 11563
  • Toll Free: 866-239-5777
  • Tel: 516-239-5777
  • Fax: 516-239-7208
  • Email Sales: sales@signaltransformer.com
  • Email Tech Help: techhelp@signaltransformer.com

2411272146_Bel-Fuse-CL2-20-24_C17431486.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max