Specifications
Frequency Range:
50Hz;60Hz
DCR Primary Side (Max):
81Ω
Mfr. Part #:
ART-B22-D125
Key Attributes
Model Number: ART-B22-D125
Product Description

Product Overview

The LEM ART Series Split Core Rogowski Coil is an accurate, reliable, and easy-to-install energy sensor designed for future Smart Cities. It offers a flexible, non-intrusive solution for AC current measurement with galvanic separation. Featuring patented Perfect Loop Technology, it minimizes positioning and external conductor influence, making it ideal for a wide range of applications including MV/LV substations, power metering, building sub-metering, power quality monitoring, and fault detection.

Product Attributes

  • Brand: LEM
  • Product Series: ART Series
  • Technology: Perfect Loop Technology
  • Certifications: IEC 61010-1, IEC 61010-2-32, IEC 61869-1, IEC 61869-2, IEC 61869-6, IEC 61869-10, UL 61010-1
  • Output Signal: 22.5 mV/kA
  • Case Material: V0 (According to UL 94)
  • IP Rating: IP57
  • Insulation: 1000 V Cat III PD2
  • Termination: 2 stripped wires
  • Intended Use: For use in electric/electronic equipment; not intended for outdoor use.

Technical Specifications

Parameter Symbol Unit ART-B22-D70 ART-B22-D125 ART-B22-D175 ART-B22-D300 Comment
Sensing Aperture Diameter mm 70 125 175 300
Output Cable Length m 1.5 (Other lengths available) 1.5 (Other lengths available) 1.5 (Other lengths available) 1.5 (Other lengths available) See page 8 for other lengths
Coil Diameter mm 6.1 6.1 6.1 6.1 Very flexible and thin coil
Ambient Operating Temperature TA C -40 to 80 -40 to 80 -40 to 80 -40 to 80
Accuracy Class 0.5 (IEC 61869-2) 0.5 (IEC 61869-2) 0.5 (IEC 61869-2) 0.5 (IEC 61869-2)
Rated Insulation Voltage V 1000 1000 1000 1000 Cat III PD2
Mass m g 124 130 138 155 (Cable length: 1.5 m)
Rated short-time thermal current Ith kA 300 @ 50 Hz 300 @ 50 Hz 300 @ 50 Hz 300 @ 50 Hz (2)
Rated transformation ratio kra kA/V 44.44 @ 50 Hz 44.44 @ 50 Hz 44.44 @ 50 Hz 44.44 @ 50 Hz
Frequency Bandwidth (3 dB) BW kHz 420 373 350 300 (3)
Phase displacement @ 50/60 Hz 0.004 0.004 0.004 0.004 (3, 4)
Ratio error (centered) % -0.5 to 0.5 -0.5 to 0.5 -0.5 to 0.5 -0.5 to 0.5 Class 0.5 accuracy according to IEC 61869-2
Ratio error (all positions) % -0.75 to 0.75 -0.75 to 0.75 -0.75 to 0.75 -0.75 to 0.75 (5) Including positioning error
Influence of external current I ext % 0.2 to 0.4 0.2 to 0.4 0.2 to 0.4 0.2 to 0.4 (6)

Notes:

  • 1) The Rogowski coil can measure any primary current as there is no saturation effect.
  • 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts).
  • 3) Frequency bandwidth and phase shift modeling schematic can be provided on request.
  • 4) Referring to the main phase offset of 90 (a Rogowski coil is a derivative current transducer).
  • 5) Considering a primary conductor of at least 15 mm, perpendicular and in contact with the Rogowski coil.