Pulse Transformers IT Series with Double Secondary Winding
The Pulse Transformers IT series with double secondary winding offers galvanic separation between drive and power circuits, providing voltage resistance up to 4 kV and ignition currents up to 1 A. These transformers are designed for various switching applications, power supplies, and data transmission, featuring vacuum potting for very low partial discharge effects and PCB through-hole mounting. Custom-specific versions are available upon request.
Product Attributes
- Brand: Schaffner
- Materials: UL 94 V-0 listed
- Certifications: UL 94 V-0
Technical Specifications
| Model | Turns Ratio | Ignition Current (Iign) [A] | Nominal Operating Voltage (Unom) [V] | Voltage Resistance (Up) [kV] | V0t [kVs] | Rise Time (tr) [s] | Primary Inductance (Lp) [mH] | Stray Inductance (Lstr) [H] | Resistance (Rp) [] | Resistance (Rs) [] | Capacitance (Ck) [pF] | Weight [g] |
| IT 143 | 1:1:1 | 0.025 | 500 | 4 | 800 | 0.6 | 15 | 200 | 3 | 3 | 10 | 2 |
| IT 242 | 1:1:1 | 0.1 | 500 | 3.2 | 250 | 0.9 | 2.5 | 75 | 0.75 | 0.75 | 7 | 6 |
| IT 243 | 1:1:1 | 0.1 | 500 | 3.2 | 250 | 1 | 2.5 | 85 | 0.8 | 0.8 | 7 | 6 |
| IT 213 | 1:1:1 | 0.25 | 380 | 2.5 | 450 | 0.4 | 6.5 | 20 | 1.4 | 1.4 | 40 | 9 |
| IT 233 | 1:1:1 | 0.25 | 500 | 4 | 300 | 1.3 | 3 | 45 | 0.8 | 0.8 | 7 | 13 |
| IT 253 | 1:1:1 | 0.25 | 500 | 3.2 | 160 | 1.3 | 1.1 | 45 | 0.55 | 0.55 | 6 | 6 |
| IT 312 | 1:1:1 | 0.25 | 380 | 2.5 | 1200 | 1 | 21 | 35 | 2.4 | 2.7 | 30 | 24 |
| IT 313 | 1:1:1 | 1 | 380 | 2.5 | 450 | 0.6 | 3 | 6 | 0.33 | 0.4 | 27 | 24 |
| IT 249 | 2:1:1 | 0.25 | 500 | 3.2 | 330 | 4 | 17 | 140 | 3.1 | 1.5 | 9 | 6 |
| IT 244 | 3:1:1 | 0.1 | 500 | 3.2 | 200 | 0.7 | 15 | 70 | 2.8 | 0.9 | 9 | 6 |
| IT 234 | 3:1:1 | 0.25 | 500 | 4 | 280 | 1 | 17 | 40 | 2 | 0.7 | 9 | 13 |
| IT 314 | 3:1:1 | 1 | 380 | 2.5 | 500 | 1 | 35 | 20 | 1.6 | 0.7 | 30 | 25 |
Note: Lp primary inductance measured at 1 kHz (secondary coil open). Lstr stray inductance measured at the secondary side, short circuit at the primary side. If there are several secondary coils, only one at a time is connected (measuring frequency 10 kHz). Tolerance for Lp: +50%; -30%.