quality pulse transformer TE Schaffner IT260 with ignition current up to 3 A and voltage resistance reaching 8 kV factory
<
quality pulse transformer TE Schaffner IT260 with ignition current up to 3 A and voltage resistance reaching 8 kV factory
>
Specifications
Turns Ratio:
3:1
Operating Temperature:
-25℃~+70℃
Mfr. Part #:
IT260
Package:
Through Hole,17.6x16.7mm
Key Attributes
Model Number: IT260
Product Description

Product Overview

The Schaffner IT series pulse transformers provide galvanic isolation between drive and power circuits, offering voltage resistance up to 8 kV and ignition currents up to 3 A. Designed for transformer-coupled gate drives, they feature negligible delays and voltage scaling capabilities. Available with single or double secondary windings, these transformers ensure rapid availability of standard gate drive solutions with a wide selection of turns ratios, ignition currents, and voltages.

Product Attributes

  • Brand: Schaffner
  • Series: IT
  • Certifications: UL 94 V-0 listed materials
  • Mounting: PCB through hole mounting or faston types
  • Customization: Custom-specific versions on request

Technical Specifications

ModelTurns RatioIgnition Current (Iign) [A]Nominal Voltage (Unom) [V]Test Voltage (Up) [kV]Voltage Rise (V0t) [Vs]Rise Time (tr) [s]Primary Inductance (Lp) [mH]Stray Inductance (Lstr) [H]Primary Resistance (Rp) []Secondary Resistance (Rs) []Capacitance (Ck) [pF]Weight [g]
IT 1551:10.1500448015851.21.2613
IT 2451:10.175045001.281001.481.48106
IT 2371:10.255002.51100125351.92.25014
IT 2391:10.25100063002.33800.90.9513
IT 2551:10.2575042501.12.2400.80.886
IT 2581:117503.22500.252.530.620.75806
IT 3701:111000540000.60.360.160.184071
IT 364**1:133000850001.71.5100.160.1435220
IT 2462:10.175042000.47352.11.176
IT 2482:10.257503.23502.217803.21.696
IT 2603:10.15003.22000.3123020.886

* Tolerance: +50%; -30% for Inductance (Lp).
** Not suitable for PCB-mounting.

Explanations:
tr rise time at given load resistor R and 70% of the output pulse height.
Lp primary inductance measured at 1 kHz (secondary coil open).
Lstr stray inductance measured at the secondary side, short circuit at the primary side. If there are several secondary coils only one at the time is connected (measuring frequency 10 kHz).
The ignition current is a set peak value where the voltage drop over the coil resistance is still insignificant (mostly below 1 V).