Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Gate Drive Transformer TE Schaffner IT364 with 8 kV Voltage Resistance and Ignition Current up to 3 A factory
<
quality Gate Drive Transformer TE Schaffner IT364 with 8 kV Voltage Resistance and Ignition Current up to 3 A factory
>
Specifications
Turns Ratio:
1:1
Width:
50mm
Length:
50mm
Operating Temperature:
-25℃~+70℃
Mfr. Part #:
IT364
Package:
Through Hole,50x50mm
Key Attributes
Model Number: IT364
Product Description

Product Overview

The Schaffner IT series pulse transformers provide galvanic separation between drive and power circuits, offering voltage resistance up to 8 kV and ignition currents up to 3 A. Designed for transformer-coupled gate drives, they feature negligible delays, voltage scaling capabilities, and are available with single or double secondary windings. These transformers ensure rapid availability of standard gate drive solutions with a wide selection of turns ratios, ignition currents, and voltages.

Product Attributes

  • Brand: Schaffner
  • Series: IT
  • Certifications: UL 94 V-0 listed materials
  • Mounting: PCB through hole mounting or faston types
  • Customization: Custom-specific versions on request

Technical Specifications

ModelTurns RatioIgnition Current (Iign) [A]Nominal Voltage (Unom) [V]Test Voltage (Up) [kV]Voltage Rise (V0t) [Vs]Rise Time (tr) [s]Primary Inductance (Lp) [mH]Weight [g]Connections
IT 1551:10.15004480151302
IT 2451:10.175045001.28602
IT 2371:10.255002.511001251402
IT 2391:10.25100063002.331302
IT 2551:10.2575042501.12.2602
IT 2581:117503.22500.252.5602
IT 3701:111000540000.60.37102
IT 364**1:133000850001.71.522005
IT 2462:10.175042000.47602
IT 2482:10.257503.23502.217602
IT 2603:10.15003.22000.312602

Notes:

  • * Tolerance: +50%; -30% for Inductance (Lp).
  • ** IT 364 is not suitable for PCB-mounting.
  • tr: rise time at given load resistor R and 70% of the output pulse height.
  • Lp: primary inductance measured at 1 kHz (secondary coile open).
  • Lstr: stray inductance measured at the secondary side, short circuit at the primary side. If there are several secondary coils only one at the time is connected (measuring frequency 10 kHz).
  • The ignition current is a set peak value where the voltage drop over the coil resistance is still insignificant (mostly below 1 V).

General Technical Data:

  • Nominal operating voltage: Up to 3000 V
  • Operating frequency: 40 kHz max. / 500 kHz max. for data transmission
  • DC to 40000 Hz
  • Voltage resistance: Up to 8 kV
  • Test voltage: Up/50 Hz/2 s max. according to VDE 110b
  • Max. partial discharge voltage: 1.5 x Unom
  • Temperature range (operation and storage): -25C to +70C (25/70/21)
  • Flammability: corresponding to UL 94 V-0 listed materials

Typical Applications:

  • Gate drive circuit
  • Power supplies
  • Power converters
  • Frequency converters
  • Switching applications
  • DC/DC converters
  • Line coupling transformers in high-speed data transmission

2411272239_TE---Schaffner-IT364_C5657622.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max